| Single
Chip Control With our Zeus Series Inverter Design |
Technical
Specification |
| Type
Of Design |
Series
Inverter (30KW - 1500 KW) |
Parallel
Inverter (1500 KW- 6000 KW) |
| S. N.
|
Technical
Specifications |
Unit |
30KW-150KW |
250KW-1000KW
|
1200KW
- 2000KW |
2500KW-
4000KW |
| 1.1 |
M. F Output Power
(Nom) |
KW |
30 |
50 |
75 |
100 |
125 |
150 |
250 |
350 |
450 |
600 |
750 |
1000 |
1200 |
1500 |
1650 |
1800 |
2000 |
2500 |
3000 |
4000 |
|
|
-at input KVA
|
KVA |
35 |
60 |
90 |
115 |
145 |
175 |
265 |
400 |
515 |
685 |
850 |
1135 |
1345 |
1685 |
1853 |
2025 |
2175 |
2775 |
3275 |
4350 |
| 1.2 |
M.F, Output Power
(Max) |
KW |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
1320 |
1650 |
1815 |
1980 |
2200 |
2750 |
3275 |
4400 |
|
|
-at input KVA
|
KVA |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
1480 |
1853 |
2038 |
2227 |
2392 |
3000 |
3600 |
4775 |
| 2.0 |
Line PF |
|
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.99 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
0.97 |
| 3.0 |
Generator Input
Voltage |
Vac |
433 |
433 |
433 |
433 |
433 |
433 |
433 |
570 |
570 |
570 |
570 |
570 |
570 |
570 |
850 |
950 |
950 |
2*750 |
2*850 |
2*850 |
| 4.0 |
Frequency |
HZ |
6000 |
6000 |
3000 |
3000 |
1000 |
1000 |
1000 |
1000 |
1000 |
1000 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
| 5.0 |
M.F Output
Voltage |
Vac |
800 |
800 |
800 |
1200 |
1200 |
1200 |
1500 |
1500 |
2000 |
2000 |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
3000 |
| 6.0 |
Generator
Efficiency |
% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
99% |
97% |
97% |
97% |
97% |
97% |
97% |
97% |
97% |
| 7.0 |
Energy
Consumption-Units/Ton with clean/sized scrap for steel@ 1650 |
KWH |
825 |
800 |
730 |
700 |
655 |
610 |
605 |
585 |
580 |
570 |
570 |
565 |
560 |
560 |
550 |
545 |
545 |
540 |
540 |
530 |
| 8.0 |
Nominal Capacity
of Furnace |
Kg |
25/30 |
25/50 |
50/100 |
100 |
150 |
150 |
300 to 500 |
500to 700 |
750 to 1000 |
1000 |
1500 |
1500 to 2000 |
2000 |
3000 |
3500 |
3500 |
4000 to 5000
|
5000 |
6000 |
7000 to 8000
|
| 9.0 |
Melting rate with
clean/sized scap for steel @ 1650oc |
Kg/Hr |
40 |
70 |
105 |
150 |
200 |
250 |
440 |
640 |
840 |
1135 |
1425 |
1900 |
2250 |
2850 |
3125 |
3400 |
3750 |
4750 |
5650 |
7600 |
| 10.0 |
Cooling Tower
Capacity with Temperature drop from 42oc To 31oc |
LPM |
50 |
75 |
100 |
100 |
150 |
150 |
300 |
350 |
400 |
450 |
500 |
550 |
650 |
750 |
900 |
1000 |
1200 |
1400 |
1600 |
2000 |
| 11.0 |
Water Storage
Capacity for Emergency |
Ltrs. |
3000 |
5000 |
6000 |
7000 |
7000 |
7000 |
10000 |
12000 |
15000 |
15000 |
20000 |
20000 |
25000 |
25000 |
30000 |
30000 |
30000 |
30000 |
35000 |
40000 |
| 12.0 |
D.M. Water flow
for Static Generator |
LPM |
|
|
|
25 |
40 |
40 |
75 |
100 |
125 |
150 |
150 |
175 |
200 |
250 |
250 |
275 |
300 |
350 |
375 |
400 |
| 13.0 |
Requirement for
Make-up Water for cooling Tower |
|
1.5
% of Flow |
|
* Rugged Dura Aluminium/ Steel Structure *
Lower energy consumption * suitable for ferrous and Non-Ferrous
Melting * Higher Melt Rate * Efficient after-Sales Service |